Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2019, 06:08 AM
  • 02 1135_02 1134_04042019_234002.mp4

Date
04/04/2019
W/O
761209
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00351
PipeID
P02917
Time
11:08 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6514
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_761209_TV02318_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1135
Downstream MH
02 1134
Dir. of Survey
Downstream
Length Surveyed
339.3 ft.
Total Length
339.3 ft.
Structural Index
4
Structural Quick
524L
Structural Rating
276
O&M Index
2
O&M Quick
432M
O&M Rating
151
Overall Index
3
Overall Quick
Overall Rating
427
Pipe schematic from manhole 02 1135 to 02 1134
MH: 02 1135MH: 02 1134downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 11350 ft. MWL - Water Level, 45 %of cross sectional area0.5 ft. MGO - General Observation - CANNECTION AT MH, 6'01 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start8.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start25.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"68.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"70.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"72 ft. B - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES119.4 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - BROKEN121.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"165.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"168.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"191.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"218.5 ft. B - Fractures, from 01 to 04 o'clock, within 8 inches of joint: YES219.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"222.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"270 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"272.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"319.1 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YESR320.9 ft. RBL - Roots Ball Lateral, from 10 to 07 o'clock, 75 %, within 8 inches of joint: YES320.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"324.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"324.1 ft. RBL - Roots Ball Lateral, from 12 to 12 o'clock, 85 %, within 8 inches of joint: YES336.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish339.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1134

Observation photos (6)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

    72 ft. - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - BROKEN

    119.4 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - BROKEN

  • Fractures, from 01 to 04 o'clock, within 8 inches of joint: YES

    218.5 ft. - Fractures, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Roots Ball Lateral, from 10 to 07 o'clock, 75 %, within 8 inches of joint: YES

    320.9 ft. - Roots Ball Lateral, from 10 to 07 o'clock, 75 %, within 8 inches of joint: YES

  • Roots Ball Lateral, from 12 to 12 o'clock, 85 %, within 8 inches of joint: YES

    324.1 ft. - Roots Ball Lateral, from 12 to 12 o'clock, 85 %, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
119.4TFDBROKEN
168.3TFA
0MWM
218.5B
8.9FM
1DAGS
336.4SSS
319.1RFJ
191.4TBA
121.5TFC
0.5MGOCANNECTION AT MH, 6'0
165.7TFC
70.9TFA
64.2TBA
68.4TFC
219.5TFC
272.7TFA
339DAGS
336.5FM
0AMH02 1135
25.4SSS
324.1TFA
324.1RBL
339.3AMH02 1134
270TFC
72B
0MWL
222.3TFC
320.9RBL
320.9TFA

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-04-04T23:08:20-07:00
documentation
PROPIPE
is_lateral_inspection
false