Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2019, 08:11 AM
  • 02 1563_02 1562_29072019_013508.mp4

Date
07/29/2019
W/O
776825
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00230
PipeID
P03995
Time
1:11 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5943
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_776825_TV02328_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1563
Downstream MH
02 1562
Dir. of Survey
Downstream
Length Surveyed
245.1 ft.
Total Length
245.1 ft.
Structural Index
4
Structural Quick
4231
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole 02 1563 to 02 1562
MH: 02 1563MH: 02 1562downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15630 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES9.9 ft. FS - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES14.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start52 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"84.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"123 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"177 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"181.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"223.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"243.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish245.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1562

Observation photos (11)

  • General Observation - CONNECTION AT MH 3 O'CLOCK

    0 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK

  • General Observation - CONNECTION AT MH 9 O'CLOCK

    0 ft. - General Observation - CONNECTION AT MH 9 O'CLOCK

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    9.9 ft. - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    52 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    84.4 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    123 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    177 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    181.8 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    223.6 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

Observations (16)

DistanceCodeObservation
14.4FM
9.9FS
84.4TF
0MGOCONNECTION AT MH 3 O'CLOCK
245.1AMH02 1562
7FM
0MWM
177TF
0AMH02 1563
123TF
52TF
181.8TF
0MWL
223.6TF
0MGOCONNECTION AT MH 9 O'CLOCK
243.5FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-07-29T01:11:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false