Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2019, 08:36 AM
  • 02 1562_02 1561_29072019_015552.mp4

Date
07/29/2019
W/O
776825
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00230
PipeID
P03994
Time
1:36 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5943
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_776825_TV02328_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1562
Downstream MH
02 1561
Dir. of Survey
Downstream
Length Surveyed
244 ft.
Total Length
244 ft.
Structural Index
4
Structural Quick
4200
Structural Rating
8
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
12
Pipe schematic from manhole 02 1562 to 02 1561
MH: 02 1562MH: 02 1561downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15620 ft. MWL - Water Level, 15 %of cross sectional area4.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 8"41.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"82.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"128.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"132 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"179.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"215.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"217.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"240.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish244 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK244 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED244 ft. AMH - Downstream Manhole, Survey Ends - 02 1561

Observation photos (12)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    4.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    27.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    41.4 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    82.4 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    128.6 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    132 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    179.7 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    215.3 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"

    217.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"

  • General Observation - CONNECTION AT MH 3 O'CLOCK

    244 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK

  • General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

    244 ft. - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

Observations (17)

DistanceCodeObservation
217.7TB
82.4TF
0MWM
27.1TB
0AMH02 1562
0MWL
4.6FM
244MGOCONNECTION AT MH 3 O'CLOCK
132TB
215.3TFC
7FM
41.4TFC
128.6TFC
244MGOCONNECTION AT MH 9 O'CLOCK CAPPED
244AMH02 1561
179.7TF
240.1FM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-07-29T01:36:28-07:00
documentation
PRO PIPE
is_lateral_inspection
false