- Date
- 10/04/2019
- W/O
- 0793127
- Weather
- Dry
- Operator/Surveyor
- REVELES
- Sewer ID
- Z00668
- PipeID
- P13738
- Time
- 2:03 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I062R
- Sewer Name
- 17 DISTRICT #17 MAIN TRUNK
- City
- Altadena
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 17
- Page No.
- 06
- Purpose
- Maintenance Related
- Project
- 20191004VMR_Disrict_17_Main_Trunk
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 14.369999885559082 in.
- Upstream MH
- 17 0013
- Downstream MH
- 17 0012
- Dir. of Survey
- Downstream
- Length Surveyed
- 501 ft.
- Total Length
- 501 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 4131
- O&M Rating
- 11
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 17 0013 to 17 0012 Observation photos (4)

358.6 ft. - Roots Medium Barrell, from 12 to 03 o'clock, 30 %, within 8 inches of joint: NO

363.2 ft. - Roots Fine Joint, from 09 to 10 o'clock, within 8 inches of joint: YESR

387.5 ft. - Roots Medium Connection, from 09 to 11 o'clock, 25 %, within 8 inches of joint: NO

392.6 ft. - Roots Fine Connection, from 02 to 03 o'clock, within 8 inches of joint: NO