Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 4, 2019, 07:10 AM
  • Section#1_17 0025_17 0024__1042019__I062R.mp4

Date
10/04/2019
W/O
0793127
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00668
PipeID
P13749
Time
12:10 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I062R
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
Altadena
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
06
Purpose
Maintenance Related
Project
20191004VMR_Disrict_17_Main_Trunk
Material
Vitrified Clay Pipe
Shape
Circular
Height
14.369999885559082 in.
Upstream MH
17 0025
Downstream MH
17 0024
Dir. of Survey
Downstream
Length Surveyed
403.2 ft.
Total Length
403.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 17 0025 to 17 0024
MH: 17 0025MH: 17 0024downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02:00 AM8.6 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4"15.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"49 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"86.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"94.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"139.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"156.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"206 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"209.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"251.1 ft. RFC - Roots Fine Connection, from 12 to 02 o'clock, within 8 inches of joint: NO251.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"292.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"336.2 ft. RFC - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: NO338.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"354.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"358.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"403.2 ft. AMH - Downstream Manhole, Survey Ends - 02:34 AM

Observation photos (2)

  • Roots Fine Connection, from 12 to 02 o'clock, within 8 inches of joint: NO

    251.1 ft. - Roots Fine Connection, from 12 to 02 o'clock, within 8 inches of joint: NO

  • Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: NO

    336.2 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: NO

Observations (20)

DistanceCodeObservation
0MWL
206TF
338.2TF
49TF
403.2AMH02:34 AM
336.2RFC
354.5TF
209.9TF
251.6TF
86.2TF
94.3TF
0MWM
251.1RFC
139.8TF
156.3TF
292.9TF
0AMH02:00 AM
15.8TF
358.4TF
8.6TB

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2019-10-04T00:10:00-07:00
documentation
REVELES, OLIVER III, CASTILLO
is_lateral_inspection
false
lining
CIPP