- Date
- 08/12/2019
- W/O
- 782250
- Weather
- Dry
- Operator/Surveyor
- J. VARGAS
- Sewer ID
- Z00707
- PipeID
- P14690
- Time
- 10:58 PM
- Certificate
- U-209-8149
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6778
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECT 5
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_782250_TV18119_AUG2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0827
- Downstream MH
- 18 0826
- Dir. of Survey
- Downstream
- Length Surveyed
- 96.4 ft.
- Total Length
- 96.4 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2211
- O&M Rating
- 5
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 18 0827 to 18 0826 Observation photos (4)

2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

7.3 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start