Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2018, 06:34 AM
  • 08 0008_08 0007_23012018_225214.mp4

Date
01/23/2018
W/O
679386
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00008
Time
10:34 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5418
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_679386_TV08115_JAN2018
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
08 0008
Downstream MH
08 0007
Dir. of Survey
Downstream
Length Surveyed
299.2 ft.
Total Length
299.2 ft.
Structural Index
4
Structural Quick
5J3K
Structural Rating
457
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
461
Pipe schematic from manhole 08 0008 to 08 0007
MH: 08 0008MH: 08 0007downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00080.1 ft. MWM - Water Mark, 50 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - mag coat21 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start299.2 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH299.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK299.2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0007

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWL
2.1SAP
299.2MGOCAPPED LATERAL 9 O'CLOCK @ MH
2.1MGOmag coat
0.1MWM
0AMH08 0008
299.2SAP
299.2MGOCONNECTION AT MH 3 O'CLOCK
299.2SRV
21SRV
299.2AMH08 0007

Properties (6)

additional_info
SC347052
custom_field_two
2
customer
LACSD
datetime
2018-01-23T22:34:01-08:00
documentation
PROPIPE
is_lateral_inspection
false