Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 29, 2017, 09:53 AM
  • 08 0038_08 0037 _29122017_020225.mp4

Date
12/29/2017
W/O
679386
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00040
Time
1:53 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5299
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_679386_TV08115_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0037
Downstream MH
08 0038
Dir. of Survey
Upstream
Length Surveyed
168.9 ft.
Total Length
169 ft.
Structural Index
2
Structural Quick
2400
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 08 0037 to 08 0038
MH: 08 0037MH: 08 0038upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 00385.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"9.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES19.9 ft. CS - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES54 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"56.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES105.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"155.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"157.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES169 ft. MWL - Water Level, 5 %of cross sectional area169 ft. AMH - Downstream Manhole, Survey Begins - 08 0037169 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (4)

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    11.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    112.6 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    149.1 ft. - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    159.6 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
159.6CL
13.1TFC
169MGOCONNECTION AT MH 9 O'CLOCK
112.6CL
115TFC
63.1TF
0MWL
163.8TFC
0AMH08 0037
149.1CS
11.1CL
0MWM
169AMH08 0038

Properties (6)

additional_info
SC346773
custom_field_two
3
customer
LACSD
datetime
2017-12-29T01:53:35-08:00
documentation
PROPIPE
is_lateral_inspection