Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2018, 06:52 AM
  • 08 0007_08 0006_23012018_225909.mp4

Date
01/23/2018
W/O
679386
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00007
Time
10:52 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5418
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_679386_TV08115_JAN2018
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
08 0007
Downstream MH
08 0006
Dir. of Survey
Downstream
Length Surveyed
14.3 ft.
Total Length
14.3 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 08 0007 to 08 0006
MH: 08 0007MH: 08 0006downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00070 ft. MWL - Water Level, 60 %of cross sectional area0 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. MGO - General Observation - MAG COAT14.3 ft. AMH - Downstream Manhole, Survey Ends - 08 000614.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
14.3AMH08 0006
0AMH08 0007
0MWL
2.7SAP
14.3SAP
2.7MGOMAG COAT
0MGOCAPPED LATERAL 9 O'CLOCK @ MH
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK

Properties (6)

additional_info
SC347052
custom_field_two
2
customer
LACSD
datetime
2018-01-23T22:52:40-08:00
documentation
PROPIPE
is_lateral_inspection
false