Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 3, 2018, 10:56 AM
  • 21 1072_21 1071 _03012018_025708.mp4

Date
01/03/2018
W/O
679327
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00769
PipeID
P16197
Time
2:56 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5301
Sewer Name
21 GAREY AVENUE TRUNK
City
POMONA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
03
Purpose
Routine Assessment
Project
WO_679327_TV21012_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
21 1072
Downstream MH
21 1071
Dir. of Survey
Downstream
Length Surveyed
190.1 ft.
Total Length
190.1 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
2
O&M Quick
3112
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
13
Pipe schematic from manhole 21 1072 to 21 1071
MH: 21 1072MH: 21 1071downstream0 ft. AMH - Upstream Manhole, Survey Begins - 21 10720 ft. MGO - Reversal Inspection0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES18.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"40 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES40 ft. CS - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES70.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"116.2 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES117.5 ft. RMJ - Roots Medium Joint, from 11 to 04 o'clock, 20 %, within 8 inches of joint: YESR118.2 ft. MMC - Material Change, Other (state in comments)126.8 ft. CM - Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES126.8 ft. MMC - Material Change, Vitrified clay pipe190.1 ft. MSA - Survey Abandoned - CAM BLKD BY STEEL SLEEVE/DEBRIS190.1 ft. MGO - General Observation - STEEL SLEEVE

Observation photos (8)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

    40 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    40 ft. - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

    116.2 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Roots Medium Joint, from 11 to 04 o'clock, 20 %, within 8 inches of joint: YESR

    117.5 ft. - Roots Medium Joint, from 11 to 04 o'clock, 20 %, within 8 inches of joint: YESR

  • Material Change, Other (state in comments)

    118.2 ft. - Material Change, Other (state in comments)

  • Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

    126.8 ft. - Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - CAM BLKD BY STEEL SLEEVE/DEBRIS

    190.1 ft. - Survey Abandoned - CAM BLKD BY STEEL SLEEVE/DEBRIS

Observations (17)

DistanceCodeObservation
190.1MSACAM BLKD BY STEEL SLEEVE/DEBRIS
190.1MGOSTEEL SLEEVE
126.8CM
40RFJ
117.5RMJ
70.1TF
0AMH21 1072
0MGO
40CS
3.6CM
116.2RFJ
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
118.2MMC
18.2TFC
126.8MMC
0MWM

Properties (6)

additional_info
SC346775
custom_field_two
4
customer
LACSD
datetime
2018-01-03T02:56:46-08:00
documentation
PROPIPE
is_lateral_inspection
false