Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2018, 08:16 PM
  • Section#2_H 0406_H 0405__9282018__I0077.mp4

Date
09/28/2018
W/O
0729413
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00177
PipeID
P10840
Time
1:16 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0077
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
WHITTIER
Loc. details
Woods
Location Code
E
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20180928SHO_JOINT_OUTFALL_H_UNIT_5A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Upstream MH
H 0406
Downstream MH
H 0405
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
5
Structural Quick
5200
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
14
Pipe schematic from manhole H 0406 to H 0405
MH: H 0406MH: H 0405downstream0 ft. AMH - Upstream Manhole, Survey Begins - S/E BARREL0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. SMW - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: YES2 ft. MSA - Survey Abandoned - VIEW OF THE DOWNLEG OF THE S/E BARREL

Observation photos (2)

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Missing Wall, at 12 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0AMHS/E BARREL
2SRC
2SMW
0MWL
0MWM
2MSAVIEW OF THE DOWNLEG OF THE S/E BARREL

Properties (7)

additional_info
LOOKING AT THE DOWNLEG OF THE S/E BARREL
custom_field_three
MISSING WALL/HOLE
custom_field_two
1
customer
LACSD
datetime
2018-09-28T13:16:30-07:00
documentation
OBREGON, VENDRYES, YOUNG
is_lateral_inspection
false