Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2018, 09:31 AM
  • 22 1232_22 1231_6262018_025804.mp4

Date
06/26/2018
W/O
0712237
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00810
PipeID
P17595
Time
2:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0905
Sewer Name
22 HOLT AVENUE TRUNK
City
COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
33
Purpose
Routine Assessment
Project
20180625MDM_HOLT_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
22 1231
Downstream MH
22 1232
Dir. of Survey
Upstream
Length Surveyed
348.5 ft.
Total Length
348.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 1231 to 22 1232
MH: 22 1231MH: 22 1232upstream0 ft. AMH - Upstream Manhole, Survey Ends - 3:40AM17.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped117.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped131.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped155.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open202.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open217.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped267.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped286 ft. MGO - General Observation - 15" VCP315.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open348.5 ft. MWL - Water Level, 5 %of cross sectional area348.5 ft. AMH - Downstream Manhole, Survey Begins - 3:05AM348.5 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • General Observation - 15" VCP

    62.5 ft. - General Observation - 15" VCP

Observations (13)

DistanceCodeObservation
81.4TFCCapped
0MWL
62.5MGO15" VCP
216.6TFCCapped
146.3TBOpen
0AMH3:05AM
231.2TFCCapped
131.3TFCCapped
330.9TFCCapped
193TFOpen
348.5AMH3:40AM
0MWM
33.2TFOpen

Properties (6)

additional_info
REVERSE INSPECTION
custom_field_two
4
customer
LACSD
datetime
2018-06-26T02:31:26-07:00
documentation
MARTIN,OLIVER 111,YOUNG
is_lateral_inspection
false