Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2018, 08:49 PM
  • 02 2330_02 2329_6262018_135140.mp4

Date
06/26/2018
W/O
0712243
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00896
PipeID
P20960
Time
1:49 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7740
Sewer Name
02 ARTHUR AVENUE TRUNK
City
PARAMOUNT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
20180621DF_ARTHUR_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
02 2330
Downstream MH
02 2329
Dir. of Survey
Downstream
Length Surveyed
306 ft.
Total Length
306 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 2330 to 02 2329
MH: 02 2330MH: 02 2329downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:50 PM0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16 ft. MGP - General Photograph163.9 ft. MGP - General Photograph202.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"253 ft. MGP - General Photograph286.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"302 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish306 ft. AMH - Downstream Manhole, Survey Ends - 2:02 PM

Observation photos (5)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    16 ft. - General Photograph

  • General Photograph

    163.9 ft. - General Photograph

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    202.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • General Photograph

    253 ft. - General Photograph

Observations (11)

DistanceCodeObservation
2SSS
163.9MGP
16MGP
0AMH1:50 PM
253MGP
302SSS
0MWM
202.4TFC
0MWL
286.8TFA
306AMH2:02 PM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-06-26T13:49:37-07:00
documentation
FRANKLIN, VENDRYES, PARAISO, SHADLER
is_lateral_inspection
false