Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2018, 08:20 AM
  • 01 1202_01 1201_642018_014403.mp4

Date
06/04/2018
W/O
0708602
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00226
PipeID
P02113
Time
1:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0878R
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Maintenance Related
Project
20180604MDM_WILCOX_AVENUE_TRUNK_EXTENSION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 1202
Downstream MH
01 1201
Dir. of Survey
Downstream
Length Surveyed
302.1 ft.
Total Length
302.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4131
O&M Rating
12
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 01 1202 to 01 1201
MH: 01 1202MH: 01 1201downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM8 ft. MGO - General Observation - 15" VCP48.4 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR - 1%54.4 ft. RMJ - Roots Medium Joint, from 08 to 10 o'clock, 15 %, within 8 inches of joint: YESR59.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped109.9 ft. RFJ - Roots Fine Joint, from 09 to 10 o'clock, within 8 inches of joint: YESR - 1%122.9 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active122.9 ft. MGO - General Observation - UNMAPPED MH151.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped206.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped292.5 ft. RFL - Roots Fine Lateral, at 11 o'clock - 3%292.5 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open- 90% ROOTS302.1 ft. AMH - Downstream Manhole, Survey Ends - 2:05AM

Observation photos (3)

  • General Observation - 15" VCP

    8 ft. - General Observation - 15" VCP

  • Roots Medium Joint, from 08 to 10 o'clock, 15 %, within 8 inches of joint: YESR

    54.4 ft. - Roots Medium Joint, from 08 to 10 o'clock, 15 %, within 8 inches of joint: YESR

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open- 90% ROOTS

    292.5 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open- 90% ROOTS

Observations (16)

DistanceCodeObservation
292.5RFL3%
302.1AMH2:05AM
151.5TFCCapped
48.4RFJ1%
54.4RMJ
292.5TFDOpen- 90% ROOTS
109.9RFJ1%
0MGOConn. @ Mh, 3 O' Clock. Active
122.9MGOConn. @ Mh, 9 O' Clock. Active
0MWL
206.5TFCCapped
122.9MGOUNMAPPED MH
0MWM
0AMH1:45AM
8MGO15" VCP
59.5TFCCapped

Properties (4)

customer
LACSD
datetime
2018-06-04T01:20:34-07:00
documentation
MARTIN,REVELES,OLIVER 111,YOUNG
is_lateral_inspection
false