Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2018, 09:33 AM
  • 02 0011_02 0010_672018_030601.mp4

Date
06/07/2018
W/O
0706686
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00234
PipeID
P03037
Time
2:33 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0884
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Maintenance Related
Project
20180601MDM_ARTESIA_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 0011
Downstream MH
02 0010
Dir. of Survey
Downstream
Length Surveyed
390.5 ft.
Total Length
390.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 0011 to 02 0010
MH: 02 0011MH: 02 0010downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:00AM2 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - BROKEN PIPE15.5 ft. MGO - General Observation - 21" VCP & CIPP15.5 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - BROKEN PIPE39 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active39 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: NO76.8 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - BROKEN PIPE97.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active171.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active229.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active271.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active289.8 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active338.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open390.5 ft. AMH - Downstream Manhole, Survey Ends - 3:25AM

Observation photos (3)

  • Deposits Settled Other,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - BROKEN PIPE

    2 ft. - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - BROKEN PIPE

  • General Observation - 21" VCP & CIPP

    15.5 ft. - General Observation - 21" VCP & CIPP

  • Deposits Settled Other,  5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: NO - BROKEN PIPE

    76.8 ft. - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - BROKEN PIPE

Observations (16)

DistanceCodeObservation
390.5AMH3:25AM
229.1TBActive
0MWL
0MWM
39TBActive
338.2TBOpen
97.5TBActive
289.8TBActive
171.3TBActive
0AMH3:00AM
271.6TBActive
76.8DSZBROKEN PIPE
2DSZBROKEN PIPE
15.5MGO21" VCP & CIPP
15.5DSZBROKEN PIPE
39DAGS

Properties (7)

custom_field_three
LINER GOOD COND.
custom_field_two
4
customer
LACSD
datetime
2018-06-07T02:33:09-07:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false
lining
CIPP