Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2016, 09:35 AM
  • 16 0704_16 0703 _19072016_023550.mp4

Date
07/19/2016
W/O
582916
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01110
PipeID
P22789
Time
2:35 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3616
Sewer Name
16 ALHAMBRA ROAD RELIEF TRUNK, SECTION 2
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
WO_582916_TV16068_JULY2016
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
16 0703
Downstream MH
16 0704
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 16 0703 to 16 0704
MH: 16 0703MH: 16 0704upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. MWL - Water Level, 10 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - 16 0703

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

Observations (5)

DistanceCodeObservation
0MGOCOCKROACHES IN MANHOLE
2DAGS
2MSAVIEW OF UPLEG OF D/S SIPHON.
0MWL
0AMH16 0703

Properties (7)

additional_info
SC305795
custom_field_two
4
customer
LACSD
datetime
2016-07-19T02:35:32-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
36133