- Date
- 06/21/2017
- W/O
- 0640693
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00616
- PipeID
- P12618
- Time
- 3:25 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0569
- Sewer Name
- 15 MONROVIA OUTFALL TRUNK
- City
- MONROVIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 09
- Purpose
- Capital Improvement Program Assesment
- Project
- 20170621MDM_M0NROVIA_OUTFALL_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 15 0725
- Downstream MH
- 15 0724
- Dir. of Survey
- Downstream
- Length Surveyed
- 654.9 ft.
- Total Length
- 654.9 ft.
- Structural Index
- 4
- Structural Quick
- 5231
- Structural Rating
- 15
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 15 0725 to 15 0724 Observation photos (6)

2 ft. - General Observation - MAG COAT 80% 8:00 TO 4:00 START

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

421.9 ft. - General Observation - 80% MAG COAT

532 ft. - General Observation - 90% MAG COAT

607.9 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR POSSIBLE