Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2017, 09:35 AM
  • 05 1715_05 1714_2132017_014715.mp4

Date
02/13/2017
W/O
0607779
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00471
PipeID
P06942
Time
1:35 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO441
Sewer Name
LOMITA TRUNK
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Capital Improvement Program Assesment
Project
20170210MDM_LOMITA_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
05 1715
Downstream MH
05 1714
Dir. of Survey
Downstream
Length Surveyed
286.8 ft.
Total Length
286.8 ft.
Structural Index
2
Structural Quick
342A
Structural Rating
36
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
36
Pipe schematic from manhole 05 1715 to 05 1714
MH: 05 1715MH: 05 1714downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN0 ft. MWM - Water Mark, 30 %of cross sectional area4.8 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT6.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT6.4 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT27.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT27.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT36.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL39.8 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL46.8 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT85.3 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H114.7 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - H118.8 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL143 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL154.3 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SL154.3 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL176.3 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H197.7 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H286.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES, Finish - SLGHT286.6 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT286.8 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observation photos (6)

  • Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    6.4 ft. - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    6.4 ft. - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL

    39.8 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL

  • Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    46.8 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SL

    154.3 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - SL

  • Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL

    154.3 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL

Observations (24)

DistanceCodeObservation
85.3FCH
4.8FCSLIGHT
286.8AMH2:20AM
6.4FCSLIGHT
154.3FSSL
176.3FCH
114.7FCH
0MWL
36.6FCSL
27.5FCSLIGHT
143FCSL
286.6FCSLGHT
0MGOConn. @ Mh, 9 O' Clock. Active
154.3FSSL
118.8FCSL
39.8FSSL
27.5FCSLIGHT
0AMH1:45AM
286.6FCSLIGHT
0MGOConn. @ Mh, 3 O' Clock. OPEN
197.7FCH
6.4FCSLIGHT
46.8FSSLIGHT
0MWM

Properties (6)

custom_field_three
SPRIAL SLIGHT JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2017-02-13T01:35:43-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false