Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2016, 08:25 AM
  • 22 0515_22 0514_10152016_032837.mp4

Date
10/15/2016
W/O
0591578
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00791
PipeID
P16855
Time
1:25 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO323
Sewer Name
22 BEN LOMOND TRUNK
City
COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
26
Purpose
Routine Assessment
Project
20161015MDM_BEN_LOMOND_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
22 0515
Downstream MH
22 0514
Dir. of Survey
Downstream
Length Surveyed
443.8 ft.
Total Length
443.8 ft.
Structural Index
3
Structural Quick
3826
Structural Rating
36
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
38
Pipe schematic from manhole 22 0515 to 22 0514
MH: 22 0515MH: 22 0514downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWM - Water Mark, 30 %of cross sectional area2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES9.2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE45 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H46.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped51.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped107.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped111 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE112.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped157.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped163.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped163.3 ft. MGO - General Observation - 15"VCP208.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped213.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped217.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT217.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT222.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, FINISH - SLIGHT222.7 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES, - HAIRLINE225.3 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES - S227.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H227.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Finish227.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H231.6 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES, - H233.3 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES - H248.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES259.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped264.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped310.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped315.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped356.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped361.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped375.3 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H380.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H406.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped412.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped420.9 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H443.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped443.8 ft. AMH - Downstream Manhole, Survey Ends - 4:10AM

Observation photos (3)

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    217.6 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    217.6 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H

    227.5 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H

Observations (41)

DistanceCodeObservation
380.3FLH
375.3FCH
157.9TFCCapped
222.7FLSLIGHT
217.6FLSLIGHT
45FCH
208.5TFCCapped
356.1TFCCapped
0MWL
0MGOConn. @ Mh, 9 O' Clock. Active
259.5TFCCapped
2.6DAGS
163.3MGO15"VCP
111FCHAIRLINE
248.1FL
222.7FSHAIRLINE
51.6TFCCapped
9.2FCHAIRLINE
213.8TFCCapped
0AMH3:30AM
225.3FCS
233.3FSH
227.5FLH
0MWM
227.5FL
107.2TFCCapped
406.8TFCCapped
231.6FSH
264.5TFCCapped
361.2TFCCapped
310.5TFCCapped
217.6FLSLIGHT
420.9FCH
227.5FLH
412.1TFCCapped
443.2MGOConn. @ Mh, 9 O' Clock. Capped
443.8AMH4:10AM
163.2TFCCapped
112.7TFCCapped
46.8TFCCapped
315.5TFCCapped

Properties (6)

custom_field_three
SLIGHT FRACTURE JOINT TO JOINT LONGER
custom_field_two
3
customer
LACSD
datetime
2016-10-15T01:25:37-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false