02 1866_02 1554_1062016_123137.mp4
31.3 ft. - Material Change, Other (state in comments) - CONCRETE PIPE
34 ft. - Broken, from 04 to 08 o'clock, within 8 inches of joint: NO
35.5 ft. - Broken Soil Visible, from 01 to 06 o'clock, within 8 inches of joint: YES
36.5 ft. - Material Change, Vitrified clay pipe
50.7 ft. - Broken, from 05 to 06 o'clock, within 8 inches of joint: YES
51 ft. - General Observation - CHIPPING
66.1 ft. - Broken, from 01 to 03 o'clock, within 8 inches of joint: YES
71.3 ft. - Broken, from 08 to 11 o'clock, within 8 inches of joint: YES
76.3 ft. - Broken, from 09 to 11 o'clock, within 8 inches of joint: YES
84 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
101.9 ft. - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES
106.9 ft. - General Observation - CHIPPING
114.7 ft. - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
122.1 ft. - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES
124.7 ft. - Broken, at 11 o'clock, within 8 inches of joint: YES
126.1 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN, BROKEN, SOIL VISIBLE
127.2 ft. - Broken, from 09 to 01 o'clock, within 8 inches of joint: YES
127.5 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES, Start - POSSIBLY BROKEN
130 ft. - Broken, from 12 to 03 o'clock, within 8 inches of joint: YES
132.4 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 101.9 | FM | — |
| 71.3 | B | — |
| 117.2 | CL | — |
| 36.4 | SSS | — |
| 66.1 | B | — |
| 123.7 | TFC | — |
| 126.1 | TFD | OPEN, BROKEN, SOIL VISIBLE |
| 134.8 | CM | — |
| 36.5 | SAV | — |
| 84 | FM | POSSIBLY BROKEN |
| 0 | MWL | — |
| 45.6 | JOL | — |
| 0 | AMH | 12:30 PM, POSSIBLE 15" LINE |
| 7.1 | CL | — |
| 134.9 | MGO | ROACHES INSIDE THE MH. |
| 73.8 | DAR | — |
| 132.4 | B | — |
| 31.3 | MMC | CONCRETE PIPE |
| 75.4 | TFC | — |
| 130 | B | — |
| 77.8 | TFC | — |
| 31.3 | SSS | — |
| 51 | JSL | — |
| 35.5 | BSV | — |
| 134.8 | FL | — |
| 0 | MGO | ROACHES INSIDE THE MH. |
| 124.7 | CL | — |
| 36.5 | MMC | — |
| 31.3 | SAV | — |
| 124.7 | B | — |
| 35.5 | DAGS | GREASE/SOIL |
| 51 | MGO | CHIPPING |
| 89.2 | CM | — |
| 58.5 | MGO | CHIPPING |
| 114.7 | FM | POSSIBLY BROKEN |
| 34 | B | — |
| 68.8 | CM | — |
| 134.9 | MGO | ACTIVE CONN. INSIDE THE MH. @ 12 O'CLOCK |
| 28 | CM | — |
| 76.3 | B | — |
| 122.1 | B | — |
| 109.3 | DAR | — |
| 99.3 | MGO | CHIPPING |
| 50.7 | B | — |
| 134.8 | MGO | SLIGHT GREASE THROUGHOUT THE REACH |
| 127.2 | B | — |
| 0 | MWM | — |
| 106.9 | MGO | CHIPPING |
| 127.5 | FL | POSSIBLY BROKEN |
| 135.1 | AMH | 1:17 PM |