Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2016, 11:26 AM
  • 02 1178_02 1825_1062016_043222.mp4

Date
10/06/2016
W/O
0596932
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00236
PipeID
P04173
Time
4:26 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0313
Sewer Name
02 ATLANTIC AVENUE RELIEF TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
10161006MDM_ATLANTIC_AVENUE_RELIEF_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
02 1178
Downstream MH
02 1825
Dir. of Survey
Downstream
Length Surveyed
53.7 ft.
Total Length
53.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 1178 to 02 1825
MH: 02 1178MH: 02 1825downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 25% START53.3 ft. MGO - General Observation - MAG COAT 25% FINISH53.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING CONCRETE53.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG53.7 ft. AMH - Downstream Manhole, Survey Ends - 4:40AM

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 25% START

    2 ft. - General Observation - MAG COAT 25% START

Observations (11)

DistanceCodeObservation
53.3MGOMAG COAT 25% FINISH
53.3SSSFLAKING CONCRETE
2SSSFLAKING CONCRETE
2SAPSEVERE AGG
2MGOMAG COAT 25% START
53.7AMH4:40AM
0MWM
53.3SAPSEVERE AGG
0MGOConn. @ Mh, 9 O' Clock. OPEN
0AMH4:30AM
0MWL

Properties (6)

custom_field_three
PEELING CONCRETE-SEVERE PROJECTING AGG
custom_field_two
2
customer
LACSD
datetime
2016-10-06T04:26:39-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection