Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2016, 11:00 AM
  • 02 1981_02 1178_1062016_040545.mp4

Date
10/06/2016
W/O
0596932
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00236
PipeID
P04174
Time
4:00 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0313
Sewer Name
02 ATLANTIC AVENUE RELIEF TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
10161006MDM_ATLANTIC_AVENUE_RELIEF_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
02 1981
Downstream MH
02 1178
Dir. of Survey
Downstream
Length Surveyed
220.8 ft.
Total Length
220.8 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 02 1981 to 02 1178
MH: 02 1981MH: 02 1178downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 4:00AM0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG8.3 ft. MGO - General Observation - MAG COAT 25% START20.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE37.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG88.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE220.4 ft. MGO - General Observation - MAG COAT 50% START220.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG220.4 ft. MGO - General Observation - MAG COAT 50% FINISH220.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN220.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING CONCRETE220.8 ft. AMH - Downstream Manhole, Survey Ends - 4:20AM

Observation photos (6)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 25% START

    8.3 ft. - General Observation - MAG COAT 25% START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

    20.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    37.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

    88.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

  • General Observation - MAG COAT 50% START

    220.4 ft. - General Observation - MAG COAT 50% START

Observations (15)

DistanceCodeObservation
220.4MGOMAG COAT 50% START
2SAPSEVERE AGG
0MWL
220.8AMH4:20AM
220.4SAPSEVERE AGG
220.4MGOMAG COAT 50% FINISH
0MGOConn. @ Mh, 9 O' Clock. OPEN
88.9SSSFLAKING CONCRETE
37.6SAPSEVERE AGG
0AMH4:00AM
8.3MGOMAG COAT 25% START
220.4MGOConn. @ Mh, 9 O' Clock. OPEN
220.4SSSFLAKING CONCRETE
0MWM
20.4SSSFLAKING CONCRETE