Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 1, 2019, 05:26 AM
  • 18 0113_18 0112 _05312019_224204.mp4

Date
05/31/2019
W/O
766605
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13933
Time
10:26 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6556
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_766605_TV18083_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0113
Downstream MH
18 0112
Dir. of Survey
Downstream
Length Surveyed
196.3 ft.
Total Length
196.3 ft.
Structural Index
3
Structural Quick
3T2G
Structural Rating
390
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
394
Pipe schematic from manhole 18 0113 to 18 0112
MH: 18 0113MH: 18 0112downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK/ACTIVE0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01132 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start35.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES43 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN49.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"51.2 ft. FS - Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES60.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO79 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES81.8 ft. FS - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start91.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN98.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN149.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish194.5 ft. FS - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish194.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish195 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish195 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish196.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0112

Observation photos (7)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    4.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    35.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

    51.2 ft. - Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO

    60.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    79 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    81.8 ft. - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
35.8FL
51.2FS
143.8TFOPEN
2CM
79FL
0MWM
81.8FS
0MGOCONNECTION IN MH 3 OCLOCK/ACTIVE
43TFOPEN
194.5DAGS
49.1TFC
0MWL
196.3AMH18 0112
60.1FL
194.5FS
149.9TFC
0AMH18 0113
4.5SAP
91.8TFOPEN
98.2TFC
195CM
4.5DAGS
2SSS
194.5SAP
195SSS

Properties (6)

additional_info
SC377678
custom_field_two
3
customer
LACSD
datetime
2019-05-31T22:26:30-07:00
documentation
PROPIPE
is_lateral_inspection
false