- Date
- 06/04/2019
- W/O
- 766605
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00698
- PipeID
- P13926
- Time
- 9:52 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6559
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 22
- Purpose
- Routine Assessment
- Project
- WO_766605_TV18083_MAY2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0106
- Downstream MH
- 18 0105
- Dir. of Survey
- Downstream
- Length Surveyed
- 131.9 ft.
- Total Length
- 131.9 ft.
- Structural Index
- 3
- Structural Quick
- 3D2D
- Structural Rating
- 133
- O&M Index
- 2
- O&M Quick
- 2D00
- O&M Rating
- 50
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 183
Pipe schematic from manhole 18 0106 to 18 0105 Observation photos (3)

4.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

4.5 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

8.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start