Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2019, 06:28 AM
  • 18 0077_18 0425 _06062019_233313.mp4

Date
06/06/2019
W/O
766605
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13894
Time
11:28 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6561
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766605_TV18083_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0425
Downstream MH
18 0077
Dir. of Survey
Upstream
Length Surveyed
8.4 ft.
Total Length
8.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 18 0425 to 18 0077
MH: 18 0425MH: 18 0077upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 00770.3 ft. MGO - General Observation - CONNECTION IN MH 9 OCLOCK/ACTIVE0.3 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK/ACTIVE1.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish6.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start8.4 ft. MGO - General Observation - STOP LOG AT CONNECTION8.4 ft. AMH - Downstream Manhole, Survey Ends - 18 04258.4 ft. MWL - Water Level, 25 %of cross sectional area8.4 ft. MWM - Water Mark, 55 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    1.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
1.5SAP
0MGOSTOP LOG AT CONNECTION
0AMH18 0425
0MWL
8.1MGOCONNECTION IN MH 9 OCLOCK/ACTIVE
8.1MGOCONNECTION IN MH 3 OCLOCK/ACTIVE
0MWM
6.7SAP
8.4AMH18 0077

Properties (6)

additional_info
SC377684
custom_field_two
3
customer
LACSD
datetime
2019-06-06T23:28:23-07:00
documentation
PROPIPE
is_lateral_inspection
false