Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2019, 08:44 AM
  • 18 1248_18 0086 _06052019_020254.mp4

Date
06/05/2019
W/O
766605
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13906
Time
1:44 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6559
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766605_TV18083_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1248
Downstream MH
18 0086
Dir. of Survey
Downstream
Length Surveyed
310.9 ft.
Total Length
310.9 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
315
O&M Index
2
O&M Quick
412K
O&M Rating
128
Overall Index
2
Overall Quick
Overall Rating
443
Pipe schematic from manhole 18 1248 to 18 0086
MH: 18 1248MH: 18 0086downstream0 ft. MGO - General Observation - CONNECTION IN MH 9 OCLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 12480 ft. MWL - Water Level, 20 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start24.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES58.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES111.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"211.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"309 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish309 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish309.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish309.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish310 ft. MGO - General Observation - ROACHES @ MH310.9 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK310.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0086

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    24.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES

    58.6 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
310MGOROACHES @ MH
0MGOCONNECTION IN MH 9 OCLOCK/ACTIVE
2.7DAGS
309CM
24.9FM
309.7SAP
111.2TFC
211.4TFC
0MWM
2CM
310.9MGOCONNECTION IN MH 3 OCLOCK
2.7SAP
0AMH18 1248
58.6DAE
0MWL
309.7DAGS
309SSS
310.9AMH18 0086
2SSS

Properties (6)

additional_info
SC377681
custom_field_two
3
customer
LACSD
datetime
2019-06-05T01:44:55-07:00
documentation
PROPIPE
is_lateral_inspection
false