- Date
- 07/19/2019
- W/O
- 771927
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00709
- PipeID
- P14712
- Time
- 1:05 AM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5933
- Sewer Name
- 18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
- City
- NORWALK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 34
- Purpose
- Routine Assessment
- Project
- WO_771927_TV18101_JUN2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 51 in.
- Width
- 51 in.
- Upstream MH
- 18 0857
- Downstream MH
- 18 0856
- Dir. of Survey
- Downstream
- Length Surveyed
- 70.1 ft.
- Total Length
- 70.1 ft.
- Structural Index
- 3
- Structural Quick
- 3B2A
- Structural Rating
- 61
- O&M Index
- 2
- O&M Quick
- 412A
- O&M Rating
- 30
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 91
Pipe schematic from manhole 18 0857 to 18 0856 Observation photos (6)

0 ft. - Upstream Manhole, Survey Begins - 18 0857

2 ft. - General Observation - MAG COAT THROUGHOUT

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

9.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

16 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

63 ft. - Alignment Left, 10 %, Start