Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 2, 2019, 09:30 AM
  • 32 0254_32 0125_10022019_023953.mp4

Date
10/02/2019
W/O
787483
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19871
Time
2:30 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7026
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_787483_TV32016_SEP2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 0125
Downstream MH
32 0254
Dir. of Survey
Upstream
Length Surveyed
175.4 ft.
Total Length
175.4 ft.
Structural Index
3
Structural Quick
3F2F
Structural Rating
165
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
165
Pipe schematic from manhole 32 0125 to 32 0254
MH: 32 0125MH: 32 0254upstream0 ft. MGO - General Observation - STOP LOG MH0 ft. AMH - Upstream Manhole, Survey Ends - 32 02542.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish2.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish165.4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start165.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start173.4 ft. MGO - General Observation - MAG COATING THROUGHOUT175.4 ft. MWL - Water Level, 10 %of cross sectional area175.4 ft. AMH - Downstream Manhole, Survey Begins - 32 0125

Observation photos (4)

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - STOP LOG MH

    175.4 ft. - General Observation - STOP LOG MH

Observations (9)

DistanceCodeObservation
172.6SAP
2MGOMAG COATING THROUGHOUT
0MWL
10SAP
172.6SSS
175.4MGOSTOP LOG MH
0AMH32 0125
175.4AMH32 0254
10SSS

Properties (5)