Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 21, 2019, 04:22 PM
  • 02 1614_02 1613_21082019_094251.mp4

Date
08/21/2019
W/O
777261
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00230
PipeID
P04018
Time
9:22 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6789
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
E LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_777261_TV02003_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1614
Downstream MH
02 1613
Dir. of Survey
Downstream
Length Surveyed
129.1 ft.
Total Length
129.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2D11
O&M Rating
51
Overall Index
2
Overall Quick
Overall Rating
51
Pipe schematic from manhole 02 1614 to 02 1613
MH: 02 1614MH: 02 1613downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 16140 ft. MWL - Water Level, 30 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start121.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"128 ft. MGO - General Observation - Possible surface spaling, from 8 to 4 oclock, throughout the reach.128.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish129.1 ft. MGO - General Observation - CONNECTION AT THE MH 5 O'CLOCK129.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1613

Observations (10)

DistanceCodeObservation
128.2DAGS
129.1MGOCONNECTION AT THE MH 5 O'CLOCK
0AMH02 1614
0MWL
128MGOPossible surface spaling, from 8 to 4 oclock, throughout the reach.
2DAGS
121.6TF
129.1AMH02 1613
0VC
0MWM

Properties (8)

additional_info
SC378295
custom_field_two
3
customer
LACSD
datetime
2019-08-21T09:22:28-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP
year_laid
38526