Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2019, 06:51 PM
  • 02 1611_02 1610_22082019_123422.mp4

Date
08/22/2019
W/O
777261
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00230
PipeID
P04015
Time
11:51 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6793
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
E LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_777261_TV02003_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1611
Downstream MH
02 1610
Dir. of Survey
Downstream
Length Surveyed
170.2 ft.
Total Length
170.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2F11
O&M Rating
69
Overall Index
2
Overall Quick
Overall Rating
69
Pipe schematic from manhole 02 1611 to 02 1610
MH: 02 1611MH: 02 1610downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 16100 ft. VC - Vermin Cockroach2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start29.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ROOTS INSIDE88.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"93.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS INSIDE119.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"169.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish170.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1610

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
169.9DAGS
170.2AMH02 1610
93.5TFDEBRIS INSIDE
119.9TF
29.8TFROOTS INSIDE
0MWL
0MWM
88.1TFA
2DAGS
0AMH02 1610
0VC

Properties (7)

additional_info
SC378299
custom_field_two
4
customer
LACSD
datetime
2019-08-22T11:51:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
PVCP-Folded/Reformed