Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2019, 07:59 AM
  • 02 1565_02 1564_30072019_013138.mp4

Date
07/30/2019
W/O
777261
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00230
PipeID
P03997
Time
12:59 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5944
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
E LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_777261_TV02003_JUL2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1565
Downstream MH
02 1564
Dir. of Survey
Downstream
Length Surveyed
331.5 ft.
Total Length
331.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2L00
O&M Rating
132
Overall Index
2
Overall Quick
Overall Rating
138
Pipe schematic from manhole 02 1565 to 02 1564
MH: 02 1565MH: 02 1564downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15650 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"62 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"89.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"120.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"179.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"217.5 ft. LFW - Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO228.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"238.2 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"243.3 ft. LFW - Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO331 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish331.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1564331.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (10)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    7.6 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    62 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    89.7 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    120.4 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    179.2 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO

    217.5 ft. - Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

    228.2 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 8"

  • Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

    238.2 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

  • Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO

    243.3 ft. - Lining Failure Wrinkled, at 04 o'clock, within 8 inches of joint: NO

  • General Observation - CONNECTION AT MH 9 O'CLOCK

    331.5 ft. - General Observation - CONNECTION AT MH 9 O'CLOCK

Observations (16)

DistanceCodeObservation
331DAGS
179.2TF
238.2TB
2DAGS
62TF
0MWM
89.7TF
217.5LFW
243.3LFW
331.5AMH02 1564
228.2TFC
331.5MGOCONNECTION AT MH 9 O'CLOCK
7.6TF
120.4TF
0AMH02 1565
0MWL

Properties (7)

custom_field_two
3
customer
LACSD
datetime
2019-07-30T00:59:09-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP
year_laid
38526