08 0217_08 0216 _29072019_033116.mp4
3.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
4.8 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
22.3 ft. - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES
58.6 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES
62.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 350.1 | DAGS | — |
| 62.9 | FM | — |
| 62.9 | CM | — |
| 3.7 | DAGS | — |
| 58.6 | FS | — |
| 0 | MWM | — |
| 352.5 | MGO | CONNECTIONS AT BOTH 3 AND 9 O' CLOCK AT MH CAPPED |
| 352.5 | AMH | 08 0216 |
| 50.5 | FH2 | — |
| 0 | MGO | CONNECTIONS AT BOTH 3 AND 9 O' CLOCK AT MH CAPPED |
| 350.1 | FM | — |
| 6 | CM | — |
| 0 | AMH | 08 0217 |
| 4.8 | FH2 | — |
| 22.3 | FM | — |
| 0 | MWL | — |