Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2019, 09:22 AM
  • 15 0528_15 0590 _22072019_023458.mp4

Date
07/22/2019
W/O
776792
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00613
PipeID
P12522
Time
2:22 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6642
Sewer Name
15 LOWER AZUSA ROAD TRUNK
City
TEMPLE CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
WO_776792_TV15097_JUL2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0528
Downstream MH
15 0590
Dir. of Survey
Downstream
Length Surveyed
239.6 ft.
Total Length
239.6 ft.
Structural Index
3
Structural Quick
3H2F
Structural Rating
206
O&M Index
2
O&M Quick
412I
O&M Rating
100
Overall Index
2
Overall Quick
Overall Rating
306
Pipe schematic from manhole 15 0528 to 15 0590
MH: 15 0528MH: 15 0590downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - STOP LOG CONNECTION AT MH 6 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 15 05282 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start65.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start136 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"145.2 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"163.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"196.5 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"214.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"223.9 ft. TBI - Tap Break-In Intruding, at 09 o'clock, -, #v, within 8 inches of joint: NO, 6", 2"237 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish237 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish237 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish239.6 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK239.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE239.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0590

Observation photos (6)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    65.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 09 o'clock, -, #v, within 8 inches of joint: NO, 6", 2"

    223.9 ft. - Tap Break-In Intruding, at 09 o'clock, -, #v, within 8 inches of joint: NO, 6", 2"

  • General Observation - COCKROACHES IN MANHOLE

    239.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (20)

DistanceCodeObservation
239.6MGOACTIVE CONNECTION AT MH 3 O'CLOCK
136TFA
214.9TFC
163.2TFC
0MWM
223.9TBI
0MWL
196.5TBA
239.6MGOCOCKROACHES IN MANHOLE
0MGOSTOP LOG CONNECTION AT MH 6 O'CLOCK
65.3SSS
145.2TBA
237SAP
2DAGS
0MGOCOCKROACHES IN MANHOLE
239.6AMH15 0590
237SSS
5.5SAP
237DAGS
0AMH15 0528

Properties (6)

additional_info
SC378309
custom_field_two
2
customer
LACSD
datetime
2019-07-22T02:22:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false