Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2019, 08:43 AM
  • B 0769_15 0589 _22072019_015024.mp4

Date
07/22/2019
W/O
776792
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00613
PipeID
P12520
Time
1:43 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6642
Sewer Name
15 LOWER AZUSA ROAD TRUNK
City
TEMPLE CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
WO_776792_TV15097_JUL2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0589
Downstream MH
B 0769
Dir. of Survey
Upstream
Length Surveyed
45.5 ft.
Total Length
45.5 ft.
Structural Index
3
Structural Quick
3900
Structural Rating
27
O&M Index
2
O&M Quick
2900
O&M Rating
18
Overall Index
3
Overall Quick
Overall Rating
45
Pipe schematic from manhole 15 0589 to B 0769
MH: 15 0589MH: B 0769upstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - B 07690.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish39.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"43.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start45.5 ft. MWL - Water Level, 5 %of cross sectional area45.5 ft. AMH - Downstream Manhole, Survey Begins - 15 058945.5 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
44.9DAGS
6.3TFC
0MWL
2SAP
0AMH15 0589
0MWM
45.5MGOCOCKROACHES IN MANHOLE
44.9SAP
45.5MGOACTIVE CONNECTION AT MH 3 O'CLOCK
2DAGS
45.5AMHB 0769

Properties (6)

additional_info
SC378309
custom_field_two
3
customer
LACSD
datetime
2019-07-22T01:43:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false