Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2017, 10:18 AM
  • 05 1366_05 1365 _11132017_021827.mp4

Date
11/13/2017
W/O
668908
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00444
PipeID
P06583
Time
2:18 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5216
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_668908_TV05031_NOV2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1366
Downstream MH
05 1365
Dir. of Survey
Downstream
Length Surveyed
364.6 ft.
Total Length
364.6 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
216
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
220
Pipe schematic from manhole 05 1366 to 05 1365
MH: 05 1366MH: 05 1365downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13660 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start66.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"86.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"116.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"166.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"214.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"264.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"315.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"358.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"362.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish364.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1365364.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
362.7SAP
358.2TFC
2SAP
0AMH05 1366
0MWL
166.9TFC
264.8TFC
214.6TFC
0MWM
116.7TFA
66.2TFC
86.9TFA
315.1TFA
364.6AMH05 1365
364.6MGOCOCKROACHES IN MANHOLE

Properties (6)

additional_info
SC346087
custom_field_two
2
customer
LACSD
datetime
2017-11-13T02:18:11-08:00
documentation
PRO PIPE
is_lateral_inspection
false