Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2017, 12:13 PM
  • 05 1410_05 1358 _11082017_041349.mp4

Date
11/08/2017
W/O
668908
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00444
PipeID
P06575
Time
4:13 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5213
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_668908_TV05031_NOV2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1358
Downstream MH
05 1410
Dir. of Survey
Upstream
Length Surveyed
4.3 ft.
Total Length
4.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1358 to 05 1410
MH: 05 1358MH: 05 1410upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 14102.1 ft. SAP - Surface Aggregate Projecting, from 08 to 08 o'clock, within 8 inches of joint: YES4.3 ft. AMH - Downstream Manhole, Survey Begins - 05 13584.3 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 08 o'clock, within 8 inches of joint: YES

    2.2 ft. - Surface Aggregate Projecting, from 08 to 08 o'clock, within 8 inches of joint: YES

Observations (4)

DistanceCodeObservation
4.3AMH05 1410
0AMH05 1358
0MWL
2.2SAP

Properties (6)

additional_info
SC346084
custom_field_two
2
customer
LACSD
datetime
2017-11-08T04:13:13-08:00
documentation
PRO PIPE
is_lateral_inspection
false