Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2017, 07:21 AM
  • 05 1344_05 1343 _11082017_232134.mp4

Date
11/08/2017
W/O
668908
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00444
PipeID
P06561
Time
11:21 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5214
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_668908_TV05031_NOV2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1344
Downstream MH
05 1343
Dir. of Survey
Downstream
Length Surveyed
426.6 ft.
Total Length
426.6 ft.
Structural Index
3
Structural Quick
513P
Structural Rating
260
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
260
Pipe schematic from manhole 05 1344 to 05 1343
MH: 05 1344MH: 05 1343downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 05 13440 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start48 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"50.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.7 ft. HSV - Hole Soil Visible, at 12 o'clock, within 8 inches of joint: YES145.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"148.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"197.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"243.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"246.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"286.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"292.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"340.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"343.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"389.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"392.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"425 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish425 ft. MGO - General Observation - COCKROACHES IN MANHOLE426.6 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK426.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1343426.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole Soil Visible, at 12 o'clock, within 8 inches of joint: YES

    127.7 ft. - Hole Soil Visible, at 12 o'clock, within 8 inches of joint: YES

Observations (28)

DistanceCodeObservation
243.4TFC
0MGOCOCKROACHES IN MANHOLE
197.1TFC
96.9TFC
48TFC
426.6MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0AMH05 1344
389.7TFC
294.8TFC
0MWM
426.6AMH05 1343
148.2TFA
392.4TFC
425SAP
145.6TFC
426.6MGOCOCKROACHES IN MANHOLE
425MGOCOCKROACHES IN MANHOLE
127.7HSV
50.4TFC
194.7TFC
246.2TFC
2SAP
0MWL
340.9TFC
286.7TFC
292.3TFC
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
343.6TFC

Properties (6)

additional_info
SC346085
custom_field_two
2
customer
LACSD
datetime
2017-11-08T23:21:21-08:00
documentation
PRO PIPE
is_lateral_inspection
false