Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2017, 10:19 AM
  • 05 1332A_05 1332 _11142017_022013.mp4

Date
11/14/2017
W/O
668908
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00444
PipeID
P06549
Time
2:19 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5218
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_668908_TV05031_NOV2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 1332A
Downstream MH
05 1332
Dir. of Survey
Downstream
Length Surveyed
159.9 ft.
Total Length
159.9 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
96
O&M Index
2
O&M Quick
423A
O&M Rating
107
Overall Index
3
Overall Quick
Overall Rating
203
Pipe schematic from manhole 05 1332A to 05 1332
MH: 05 1332AMH: 05 1332downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 1332A0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start7.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 11 o'clock, , within 8 inches of joint: YES7.2 ft. ID - Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES37 ft. ID - Infiltration Dripper, from 10 to 03 o'clock, within 8 inches of joint: YES100.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"110.6 ft. IR - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES114.2 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS159.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish159.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish159.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1332159.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK159.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 11 o'clock,  , within 8 inches of joint: YES

    7.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 10 to 11 o'clock, , within 8 inches of joint: YES

  • Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES

    7.2 ft. - Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, from 10 to 03 o'clock, within 8 inches of joint: YES

    37 ft. - Infiltration Dripper, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

    110.6 ft. - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
0AMH05 1332A
37ID
159.9DAGS
159.9SAP
100.4TB
159.9AMH05 1332
0MWM
7.2DAE
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
110.6IR
0MWL
159.9MGOACTIVE CONNECTION AT MH 3 O'CLOCK
2DAGS
2SAP
7.2ID
114.2DSZDEBRIS
159.9DSZ

Properties (6)

additional_info
SC346089
custom_field_two
2
customer
LACSD
datetime
2017-11-14T02:19:33-08:00
documentation
PRO PIPE
is_lateral_inspection
false