Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2017, 10:31 AM
  • 05 1365_05 1364 _11132017_023203.mp4

Date
11/13/2017
W/O
668908
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00444
PipeID
P06582
Time
2:31 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5216
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
WO_668908_TV05031_NOV2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1365
Downstream MH
05 1364
Dir. of Survey
Downstream
Length Surveyed
144.5 ft.
Total Length
144.5 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
87
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
91
Pipe schematic from manhole 05 1365 to 05 1364
MH: 05 1365MH: 05 1364downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 05 13650 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start49.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"100.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"144.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish144.5 ft. AMH - Downstream Manhole, Survey Ends - 05 1364144.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
144.5SAP
0MGOCOCKROACHES IN MANHOLE
0AMH05 1365
144.5AMH05 1364
100.5TFC
49.6TF
0MWL
0MWM
2SAP
144.5MGOCOCKROACHES IN MANHOLE

Properties (6)

additional_info
SC346087
custom_field_two
2
customer
LACSD
datetime
2017-11-13T02:31:44-08:00
documentation
PRO PIPE
is_lateral_inspection
false