- Date
- 11/08/2017
- W/O
- 668908
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00444
- PipeID
- P06563
- Time
- 10:55 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5214
- Sewer Name
- 05 GARDENA PUMP TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_668908_TV05031_NOV2017
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 1346
- Downstream MH
- 05 1345
- Dir. of Survey
- Downstream
- Length Surveyed
- 440.9 ft.
- Total Length
- 440.9 ft.
- Structural Index
- 3
- Structural Quick
- 3P00
- Structural Rating
- 261
- O&M Index
- 2
- O&M Quick
- 2a00
- O&M Rating
- 342
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 603
Pipe schematic from manhole 05 1346 to 05 1345 Observation photos (3)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

20.7 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS