- Date
- 07/18/2019
- W/O
- 776971
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00705
- PipeID
- P14356
- Time
- 9:58 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6639
- Sewer Name
- 18 SOUTH PLANT OUTFALL TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_776971_TV18180_JUL2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0502
- Downstream MH
- 18 0501
- Dir. of Survey
- Downstream
- Length Surveyed
- 406.8 ft.
- Total Length
- 406.8 ft.
- Structural Index
- 3
- Structural Quick
- 413Q
- Structural Rating
- 274
- O&M Index
- 2
- O&M Quick
- 3A2O
- O&M Rating
- 192
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 466
Pipe schematic from manhole 18 0502 to 18 0501 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

9.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

210.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

346.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start