Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 25, 2019, 04:45 PM
  • H 0647_H 0646_9252019_100447.mp4

Date
09/25/2019
W/O
0792939
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00192
PipeID
P11053
Time
9:45 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8092
Sewer Name
H JOINT OUTFALL H - UNIT 8J
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20190925SHO_JOINT_OUTFALL_H_UNIT_8J
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
H 0647
Downstream MH
H 0646
Dir. of Survey
Downstream
Length Surveyed
341.3 ft.
Total Length
341.3 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole H 0647 to H 0646
MH: H 0647MH: H 0646downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 06470 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area7.4 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start7.4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start51.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"55.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"90.3 ft. FM - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES100.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"145.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"169.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"203 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"287.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"308.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"339.5 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish339.5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish341.3 ft. MGO - General Observation - ACTIVE CONNECTION IN THE MH @ 3341.3 ft. AMH - Downstream Manhole, Survey Ends - MH 0646

Observation photos (2)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    7.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    90.3 ft. - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
169.4TFC
308.2TF
203TF
339.5SSS
339.5SAV
51.2TFC
100.3TF
341.3MGOACTIVE CONNECTION IN THE MH @ 3
55.9TF
7.4SSS
0AMHMH 0647
145.1TFC
7.4SAV
90.3FM
0MWL
0MWM
287.8TF
341.3AMHMH 0646

Properties (5)

additional_info
RFIR
customer
LACSD
datetime
2019-09-25T09:45:36-07:00
documentation
OBREGON, BRAR, RUVALCABA
is_lateral_inspection
false