Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 30, 2019, 12:19 PM
  • Section#7_05 2270_E 0211__9302019__I0256.mp4

Date
09/30/2019
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00484
PipeID
P24798
Time
5:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0256
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Maintenance Related
Project
20190930MDM_MANCHESTER_VERMONT_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
E 0211
Downstream MH
05 2270
Dir. of Survey
Upstream
Length Surveyed
12.9 ft.
Total Length
12.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole E 0211 to 05 2270
MH: E 0211MH: 05 2270upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:25AM0.7 ft. MGO - General Observation - MH CONN 9:00 OPEN3.8 ft. MGO - General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 9:003.8 ft. MGO - General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 3:003.8 ft. MGO - General Observation - POSSIBLE AREA OF MISSING PIPE12.9 ft. AMH - Downstream Manhole, Survey Begins - 5:20AM12.9 ft. MWM - Water Mark, 20 %of cross sectional area12.9 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (3)

  • General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 9:00

    9.1 ft. - General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 9:00

  • General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 3:00

    9.1 ft. - General Observation - POSSIBLE BROKEN PIPE FROM CHANNEL 3:00

  • General Observation - POSSIBLE AREA OF MISSING PIPE

    9.1 ft. - General Observation - POSSIBLE AREA OF MISSING PIPE

Observations (8)

DistanceCodeObservation
0AMH5:20AM
9.1MGOPOSSIBLE BROKEN PIPE FROM CHANNEL 9:00
12.9AMH5:25AM
9.1MGOPOSSIBLE BROKEN PIPE FROM CHANNEL 3:00
0MWM
9.1MGOPOSSIBLE AREA OF MISSING PIPE
0MWL
12.2MGOMH CONN 9:00 OPEN

Properties (5)

additional_info
LOOKING FOR MISSING PIPE
customer
LACSD
datetime
2019-09-30T05:19:08-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false