Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 1, 2019, 12:14 PM
  • Section#6_16 0083_16 0082__1012019__I0258R.mp4

Date
10/01/2019
W/O
0795227
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00639
PipeID
P13097
Time
5:14 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0258R
Sewer Name
16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
14
Purpose
Maintenance Related
Project
20191001MDM_ALLEN_AVENUE_TRUNK_SECTS_1_2_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
16 0083
Downstream MH
16 0082
Dir. of Survey
Downstream
Length Surveyed
125.7 ft.
Total Length
125.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 16 0083 to 16 0082
MH: 16 0083MH: 16 0082downstream0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 5:25AM82.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES125.7 ft. AMH - Downstream Manhole, Survey Ends - 5:35AM

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 04 o'clock,  , within 8 inches of joint: YES

    82.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MGOMH CONN 9:00 ACTIVE
82.7DAGS
0MWL
0MWM
0MGOMH CONN 3:00 OPEN
0AMH5:25AM
125.7AMH5:35AM

Properties (5)

additional_info
PRE ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-10-01T05:14:47-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false