Section#5_16 0084_16 0083__1012019__I0258R.mp4
33.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: NO - INSIDE LINK PIPE
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 4:45AM |
| 0 | MWL | — |
| 0 | MWM | — |
| 33.3 | DAGS | INSIDE LINK PIPE |
| 301.8 | AMH | 5:10AM |
| 26.8 | RFJ | 1% |
| 0 | MGO | MH CONN 3:00 ACTIVE |
| 0 | MGO | MH CONN 9:00 OPEN |
| 16.3 | RFJ | 1% |