- Date
- 09/24/2019
- W/O
- 0792816
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00154
- PipeID
- P09966
- Time
- 1:37 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G8091
- Sewer Name
- D JOINT OUTFALL D - UNIT 4
- City
- TORRANCE
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 20
- Purpose
- Capital Improvement Program Assesment
- Project
- 20190924SHO_JOINT_OUTFALL_D_UNIT_4
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Upstream MH
- D 0066
- Downstream MH
- 05 0064
- Dir. of Survey
- Downstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 2
- Structural Quick
- 2111
- Structural Rating
- 3
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole D 0066 to 05 0064 Observation photos (2)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

2 ft. - Survey Abandoned - ZOOMED TO MH 64