Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 21, 2019, 05:52 AM
  • H JOINT_H 0611 _20082019_225632.mp4

Date
08/20/2019
W/O
777332
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00190
PipeID
P21860
Time
10:52 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6872
Sewer Name
H JOINT OUTFALL H - UNIT 8G
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_777332_TV15075_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
H JOINT
Downstream MH
H 0611
Dir. of Survey
Downstream
Length Surveyed
8 ft.
Total Length
8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole H JOINT to H 0611
MH: H JOINTMH: H 0611downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H JOINT0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MGO - General Observation - MAG COATING THROUGHOUT0 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start7.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish8 ft. AMH - Downstream Manhole, Survey Ends - H 0611

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    0 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
7.2SAP
0MWM
0AMHH JOINT
0MWL
0MGOMAG COATING THROUGHOUT
8AMHH 0611
0SAP