Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 23, 2019, 05:16 AM
  • H 0889_H 0601 _22082019_223416.mp4

Date
08/22/2019
W/O
777332
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00190
PipeID
P11023
Time
10:16 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6876
Sewer Name
H JOINT OUTFALL H - UNIT 8G
City
LA PUENTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_777332_TV15075_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
H 0889
Downstream MH
H 0601
Dir. of Survey
Downstream
Length Surveyed
130.4 ft.
Total Length
130.4 ft.
Structural Index
3
Structural Quick
3D2D
Structural Rating
125
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
125
Pipe schematic from manhole H 0889 to H 0601
MH: H 0889MH: H 0601downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 08890 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start128.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish128.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE128.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish130.4 ft. AMH - Downstream Manhole, Survey Ends - H 0601

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    128.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
0AMHH 0889
2SAP
128.1SSS
2SSS
128.1MGOCOCKROACHES IN MANHOLE
0MWM
130.4AMHH 0601
0MGOACTIVE CONNECTION AT MH 8 O'CLOCK
0MWL
128.1SAP

Properties (7)

additional_info
SC378348
custom_field_two
3
customer
LACSD
datetime
2019-08-22T22:16:44-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27198