Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2019, 05:35 AM
  • H 1372_H 1376_29072019_224448.mp4

Date
07/29/2019
W/O
777336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00180
PipeID
P26180
Time
10:35 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6648
Sewer Name
H JOINT OUTFALL H - UNIT 5D
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_777336_TV15113_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
H 1372
Downstream MH
H 1376
Dir. of Survey
Downstream
Length Surveyed
189 ft.
Total Length
189 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
111
O&M Index
2
O&M Quick
2F00
O&M Rating
74
Overall Index
3
Overall Quick
Overall Rating
185
Pipe schematic from manhole H 1372 to H 1376
MH: H 1372MH: H 1376downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - H 13720 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COATING THROUGHOUT 50%2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start11.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish187.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish187.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK189 ft. AMH - Downstream Manhole, Survey Ends - H 1376189 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT 50%

    2 ft. - General Observation - MAG COATING THROUGHOUT 50%

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    189 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
2DAGS
187.7SAP
2MGOMAG COATING THROUGHOUT 50%
0MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
0AMHH 1372
11.6TBA
189AMHH 1376
187.7DAGS
189MGOCOCKROACHES IN MANHOLE
0MWL
187.7MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWM
2SAP

Properties (6)

additional_info
SC378315
custom_field_two
3
customer
LACSD
datetime
2019-07-29T22:35:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false