Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 23, 2019, 06:00 AM
  • H 0432_H 0431_22072019_231519.mp4

Date
07/22/2019
W/O
777336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00180
PipeID
P10887
Time
11:00 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6644
Sewer Name
H JOINT OUTFALL H - UNIT 5D
City
SOUTH EL MONTE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_777336_TV15113_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
H 0432
Downstream MH
H 0431
Dir. of Survey
Downstream
Length Surveyed
445.7 ft.
Total Length
445.7 ft.
Structural Index
3
Structural Quick
3Q2Q
Structural Rating
440
O&M Index
2
O&M Quick
412Q
O&M Rating
180
Overall Index
2
Overall Quick
Overall Rating
620
Pipe schematic from manhole H 0432 to H 0431
MH: H 0432MH: H 0431downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 04320 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start5.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start86.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"255.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"374.2 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"443.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish443.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish443.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish445.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK445.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE445.7 ft. AMH - Downstream Manhole, Survey Ends - H 0431

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    445.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (16)

DistanceCodeObservation
445.7MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0AMHH 0432
443.8SAP
445.7MGOCOCKROACHES IN MANHOLE
445.7AMHH 0431
0MGOCOCKROACHES IN MANHOLE
5.2SSS
0MWL
0MWM
5.2SAP
255.1TB
374.2TBA
2DAGS
86.5TBA
443.8DAGS
443.8SSS

Properties (6)

additional_info
SC378311
custom_field_two
3
customer
LACSD
datetime
2019-07-22T23:00:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false